3.4.4 RS-485 Connector
RS-485 is the interface that communicates the dome camera and its control
device. Please connect the control keyboard to the speed dome through the
terminal block. The recommended cables for RS-485 communication are CAT
5 cables; maximum cable length for over 24-gauge wire is 4000 feet (1219
meters). If the total cable length exceeds 4000 feet, using a repeater to
maintain the signals is recommended. Please refer to the figure and table
below for pin defination and wiring.
3.4.5 Cable Wiring and Connection
Users may need to do cable wiring when: (1) Connecting self-provided cords
to the connector housing (shown in the figure below) instead of using the
equipped data cable or (2) Connecting alarm input and output devices. The
table follows will illustrate the way to wire cords into the connector housing
(shown in the figures below). Please refer to the section 3.4.3 22-Pin
Connector Definition for the exact position of each cord.
Pin
Corresponding Pins
(22-Pin Connector)
Definition
1 7,10 T+, R+ (D+)
2~4 Reserved
5 8,9 T-, R- (D-)